< img height="1" width="1" src="https://www.facebook.com/tr?id=1883330099079707&ev=PageView &noscript=1"/>

FaceLift T30 4th Generation Endolift Dual-Wavelength Laser System

Table of Contents

In today’s high-end aesthetic market, Endolift minimally invasive laser skin tightening technology has become an important solution for facial rejuvenation and contour reshaping. Among its core technologies, the 1470nm wavelength is widely recognized as the primary operating wavelength, while dual-wavelength synergistic systems are becoming the industry upgrade trend.

The LionAura FaceLift T30 4th Generation Endolift Dual-Wavelength Laser System integrates 1470nm and 980nm dual-wavelength output, a precision energy modulation system, and a visualized safety management platform. It is specifically designed for professional physicians and high-end clinics, balancing precision, safety, and multi-scenario clinical versatility.

Analysis of 1470nm Laser and Endolift Technology Principles

Introduction to Endolift Technology

Endolift is a minimally invasive laser procedure that delivers energy into subdermal tissue through ultra-thin optical fibers.

Its core objectives are:

  • Precise fat dissolution
  • Immediate collagen fiber contraction
  • Stimulation of collagen regeneration
  • Improvement of facial laxity
  • Contour reshaping

With minimal trauma, short recovery time, and highly concentrated energy delivery, Endolift has become a highly sought-after anti-aging and contour enhancement technology in the international market.

Why Is 1470nm the Core Wavelength?

The 1470nm wavelength demonstrates high absorption in both water and fat, resulting in three key advantages:

  1. Energy is highly concentrated in target tissues
  2. Thermal diffusion is more controllable
  3. Lower risk of damage to surrounding tissues

Target layers include:

  • Subcutaneous fat layer → Disruption of fat cell structure
  • Deep dermis → Immediate collagen contraction + subsequent regeneration
  • It delivers outstanding performance in both fat reduction and skin tightening.

Dual-Wavelength System: 1470nm + 980nm Synergistic Advantages

FaceLift T30 Technical Specifications

Parameter Specification
Wavelength 1470 nm + 980 nm
Max Power 15 W + 15 W
Aiming Beam 660 nm, 200 mW
Operating Modes CW / Pulsed / Single Pulse
Pulse Width 1–1000 ms
Frequency 1–100 Hz
Power Step 0.1 W

The Role of 980nm Wavelength

  • Deeper tissue penetration
  • Improved microcirculation
  • Assists in skin tightening
  • Expandable vascular applications

Dual-Wavelength Output Modes

  • Independent output
  • Combined output
  • Customized ratio combinations
  • Physicians can precisely adjust settings according to:
  • Facial thickness variations
  • Tissue depth
  • Treatment goals

Compared with single-wavelength devices:

✔ Broader indications
✔ More comprehensive tissue coverage
✔ Greater treatment flexibility

Precision Energy Management System — Core Competitiveness

1. Adjustable Pulse Width: 1–1000 ms

Through duty cycle control:

Low pulse width → Delicate facial treatments

High pulse width → Deep tissue heating

More controllable thermal accumulation

2. Frequency Range: 1–100 Hz

Significantly exceeds traditional 1–9Hz systems:

High frequency → More uniform energy distribution

Low frequency → Stronger single-pulse effect

Wider safety window

3. 0.1W Power Increment

Adjustable from 1–15W

High-precision fine-tuning

Suitable for varying tissue thickness and treatment areas

4. Visualized Energy Management

Function Status
Real-time output power display
Accumulated total energy display
Adjustable treatment time
Laser temperature monitoring
Ambient temperature monitoring

Physicians can monitor energy accumulation in real time to avoid excessive output risks.

Intelligent Control & Operating Experience

Parameter Specification
Display 8-inch HD vivid touch screen
Cooling System Air cooling + TEC
Weight 4.5 kg
Dimensions 250 × 200 × 220 mm

8-inch high-definition touchscreen

Visualized parameter interface

Clear operating logic

Real-time data feedback

Dual Cooling System: Air + TEC

Ensures stable laser output

Extends laser lifespan

Improves continuous operation capability

Portable & Compact Design

Only 4.5 kg

Compact size

Ideal for mobile clinic use

Fiber Compatibility & Clinical Adaptability

Supported fiber diameters:

400 μm

600 μm

800 μm

Different diameters are suitable for:

Delicate facial areas

Jawline contouring

Double chin

Localized body fat

Enhanced clinical flexibility improves treatment precision.

Safety System Design

FaceLift T30 integrates:

660nm 200mW aiming beam

Real-time temperature monitoring

Power traceability

Accumulated energy display

Combined with a precision parameter management system, it significantly reduces the risk of overexposure.

Clinical Applications

  • Facial contour lifting
  • Jawline tightening
  • Double chin reduction
  • Nasolabial fold laxity improvement
  • Mild facial fat reduction
  • Neck tightening
  • Localized body contouring
  • The 980nm wavelength can also expand to:
  • Vascular-assisted treatments
  • Adjunctive pain relief applications

Why Choose FaceLift T30?

  • Dual wavelength 1470nm + 980nm
  • 1–100Hz adjustable frequency
  • 1–1000ms ultra-wide pulse range
  • 1W precision power increment
  • Visualized total energy monitoring
  • Air + TEC dual cooling system
  • 5 kg lightweight design
  • Multi-specification fiber compatibility

Conclusion

The 4th Generation Endolift Solution for the High-End Market

FaceLift T30 is not merely a parameter upgrade — it represents a comprehensive technological innovation.

Through dual-wavelength synergistic output, precision energy management, and intelligent safety monitoring, it provides aesthetic clinics, plastic surgeons, and high-end anti-aging centers with a safer, more precise, and more controllable minimally invasive laser solution for skin tightening and fat reduction.

If you are looking for an Endolift device that:

  • Meets European market standards
  • Supports personalized treatment strategies
  • Balances safety and performance

FaceLift T30 is the 4th generation solution worth your attention.

— LionAura FaceLift T30 Engineered for Professionals. Designed for Precision.

Author picture
Welcome To Share This Page:
Product Categories
Latest News
Get A Free Quote Now !
Contact Form Demo (#3)

Related Products

Related News

In today’s high-end aesthetic market, Endolift minimally invasive laser skin tightening technology has become an important solution for facial rejuvenation

In the fast-changing world of medical aesthetics, patients aren’t settling for subtle results anymore. They want that “surgical look”—but without

  If you’re in the beauty business—whether you own a small spa or work as a solo esthetician—you know the

In the competitive landscape of medical aesthetics and skin management, Hydro Dermabrasion has evolved far beyond a simple “deep clean”

Introduction In the competitive world of aesthetic medicine, salon owners face a constant dilemma: clients demand a wider variety of

In the rapidly exploding market of non-invasive aesthetic treatments, clients are increasingly demanding procedures that offer significant results with zero

The New Standard in Aesthetic Treatments In the rapidly evolving landscape of aesthetic medicine, clients are constantly seeking non-invasive solutions

Lionaura Successfully Hosts Global Endolift Experience Sharing Event Dr. Ericka Showcases Outstanding Clinical Results and Impressive Revenue Growth December 1,

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)
If you have any questions, please do not hesitate to contact us.
company lionaura best china supplier of beauty machine solution